Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 177
4.1.n.6.18 Key unset
18 Key unset
>No<
If the Key unset option is set to Yes, the zone is a key switch that unsets an area.
4.1.n.6.19 Technical full set
19 Tech full set
>No<
If the Technical full set option is set to No, the technical alarms in this zone are
disabled when the area is fully set.
4.1.n.6.20 Technical unset
20 Tech unset
>No<
If the Technical unset option is set to No, the technical alarms in this zone are
disabled when the area is unset.
4.1.n.6.21 Technical part set
21 Tech part set
>No<
If the Technical part set option is set to No, the technical alarms in this zone are
disabled when the area is partially set.
4.1.n.6.22 Keypad LCD
22 Keypad LCD
>No<
If the Keypad LCD option is set to Yes, when the zone activates, the zone name
is displayed on the keypad LCD on all keypads, related to the area.
4.1.n.6.23 Log
23 Log
>No<
The Log option determines whether the zone event is recorded in the system log.
4.1.n.6.24 CS report
24 CS report
>No<
The CS report option determines whether the zone event is reported to the
central station.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals