Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 243
6 Interconnection fault: A critical error caused by communication trouble
between internal panel components
7 Mains fault: Mains fault, including external fault
8 Battery fault: Battery fault, including external fault
9 FTC (Failed to Communicate): Alarm reporting has failed to deliver events
10 Siren fault: Siren output fault
11 Zone technical: Technical zone status
12 Keypad fault: A fault reported by keypad
13 Expander fault: A fault reported by remote expander
14 Comms fault: All transmission paths are down (no communication)
15 Engineer reset: Engineer reset requirement
16 Alarms pending: Unacknowledged alarms
8.4.2 Inhibit includes
1>Zone panic
Access level 3
The menu defines which conditions a user with particular access level is allowed
to inhibit. If a particular condition below has this option set to Access level 2 or
Access level 3, a user with this access level can inhibit it using an inhibit menu or
during set.
The following options are available.
1 Zone panic: Holdup device active
2 Zone masking: Masking / fault state on input
3 Zone fault: Intrusion detector fault
4 Zone tamper: Tamper in zone
5 Interconnection fault: A critical error caused by communication trouble
between internal panel components
6 Mains fault: Mains fault, including external fault
7 Battery fault: Battery fault, including external fault
8 FTC (Failed to Communicate): Reporting attempts are failed
9 Siren fault: Siren output fault
10 Zone technical: Technical zone status
11 Keypad fault: A fault reported by keypad
12 Expander fault: A fault reported by remote expander
13 Comms fault: All transmission paths are down (no communication)
14 Engineer reset: Engineer reset requirement
8.4.3 Part set
1>Report BA
Yes
The Part set menu allows you to configure the part set options.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals