Appendix B: Advisor Advanced reporting codes
330 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
#
SIA
code
VdS
code
CID
code
Function
Note
Reporting
priority
68.
XR
0xB0
R384
Detector or fob low
battery restore
Low
69.
XT
0x30
E384
Detector or fob low
battery
Low
70.
YC
0x37
E350
Communications fail
ISDN / GSM / voice / audio
device fail
Low
71.
YK
0xB9
R354
Communications
restore
ISDN / GSM / voice / audio
device restore
Low
72.
YR
0xB3
R302
System battery / fuse
restore
Expander / dialler battery /
fuse restore
Low
73.
YS
0x39
E354
Communication trouble
Fail To Communicate (FTC)
Low
74.
YT
0x33
E302
System battery / fuse
trouble
Expander / dialler battery low
/ fuse fault
Low
75.
ZA
0x40
E152
Technical alarm — low
temperature
Low temperature detector
alarm
Medium
76.
ZB
0x51
E570
Technical bypass —
low temperature
Low temperature detector
inhibit
Low
77.
ZJ
0xB0
R381
Technical long
supervision restore —
low temperature
Low temperature detector
long supervision restore
Low
78.
ZR
0xC0
R152
Technical restore —
low temperature
Low temperature detector
restore
Low
79.
ZS
0x30
E381
Technical long
supervision — low
temperature
Low temperature detector
long supervision alarm
Low
80.
ZU
0xD1
R570
Technical unbypass —
low temperature
Low temperature detector
uninhibit
Low
81.
YA
0x23
E321
Siren fault
Low
82.
YH
0xA3
R321
Siren restore
Low
83.
NC
0x34
E356
CS polling fail
Heartbeat inactive
Low
84.
NR
0xB4
R356
CS polling restore
Heartbeat active
Low
85.
CP
0x61
R403
Auto set
Set by schedule
Low
86.
OA
0xE1
E403
Auto unset
Unset by schedule
Low
87.
OT
0x61
E608
Late close
Postponed auto set
Low
88.
OK
0x61
R608
Early open
Manually unset before auto
unset
Low
89.
IA
0x63
E313
Engineer reset request
Low
90.
IR
0xE3
R313
Engineer reset restore
Low
91.
GA
0x73
E151
Technical alarm — gas
Gas detector alarm
High
92.
GR
0xF3
R151
Technical restore —
gas
Gas detector restore
High

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals