Chapter 2: Installation
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 25
Zone state
EOL
Connection
details [1]
Measure [2]
Short
Masking
Normal
Alarm
Fault
Open
Single NC
(Item 1)
No EOL
R (kΩ)
<1
>1
U (V)
<3.5
>3.5
Note: Values for other EOL are equal to Dual, except all ranges but normal are
alarm ranges.
Single NO
(Item 2)
No EOL
R (kΩ)
>44.70
<44.70
U (V)
>11.14
<11.14
Note: Values for other EOL are equal to Dual, except all ranges but normal are
alarm ranges.
Dual
10K
(Item 4)
R (kΩ)
<3.33
3.33
6.67
6.67
13.33
13.33–
26.67
>26.67
RA=10 kΩ, RT=5 kΩ,
RF=5
U (V)
<5.70
5.70
8.10
8.10
10.20
10.20–
11.70
>11.70
4K7
(Item 3)
R (kΩ)
<1.00
1.00
6.67
6.67
16.84
>16.84
RA=4.7 kΩ, RT=4.7
U (V)
<2.41
2.41
8.07
8.07
10.74
>10.74
4K7
(Item 4)
R (kΩ)
<1.00
1.00
3.42
3.42
6.67
6.67
16.84
>16.84
RA=4.7 kΩ, RT=2.35 kΩ,
RF=2.35
U (V)
<2.41
2.41
5.79
5.79
8.07
8.07
10.74
>10.74
4K7
(Item 7)
R (kΩ)
<1.00
16.84–
55.00
1.00
6.67
6.67
11.75
11.75–
16.84
>55.00
RA=4.7 kΩ, RT=4.7 kΩ,
RF=10
U (V)
<2.41
10.74–
12.70
2.41
8.07
8.07
9.82
9.82
10.74
>12.70
2K2
(Item 4)
R (kΩ)
<0.73
0.73
1.47
1.47
2.93
2.93
5.87
>5.87
RA=2.2 kΩ, RT=1.1 kΩ,
RF=1.1
U (V)
<1.90
1.90
3.30
3.30
5.30
5.30
7.70
>7.70
6K8
(Item 4)
R (kΩ)
<2.27
2.27
4.53
4.53
9.07
9.07
18.13
>18.13
RA=6.8 kΩ, RT=3.4 kΩ,
RF=3.4
U (V)
<4.50
4.50
6.80
6.80
9.10
9.10
11.00
>11.00
5K6
(Item 4)
R (kΩ)
<1.87
1.87
3.73
3.73
7.47
7.47
14.93
>14.93
RA=5.6 kΩ, RT=2.8 kΩ,
RF=2.8
U (V)
<3.90
3.90
6.10
6.10
8.50
8.50
10.50
>10.50

Table of Contents