Environmental
Operating temperature
0 to +40°C
Tested temperature according
EN 50131
−10 to +55°C
Humidity
95% noncondensing
IP protection grade
IP31
Colour
Beige
Dimensions
See “List of panel variantson page iii
EN 50131 grade and class
ATS1500A(-IP): Grade 2, Class II
ATS3500A(-IP): Grade 3, Class II
ATS4500A-IP: Grade 3, Class II
Note: ATS1500A(-IP)-MM can be upgraded to an EN
Grade 3 setup with the use of the ATS-MM-TK tamper
kit. ATS1500A(-IP)-SM can be upgraded to an EN
Grade 3 setup with the use of the ATS-SM-TK tamper
kit.
Safety class
Class I
Enclosure type
Enclosure (meets UL94V-0)
Overvoltage category
Category II
Maximum altitude, or minimum air
pressure
2000 m above mean sea level
Fuses
Battery
ATS1500A(-IP), ATS3500A(-IP): 2 A, resettable
ATS4500A(-IP): 3 A, resettable
12 V aux
1 A, resettable
System databus
1 A, resettable
Siren 1, high current output S1
1 A, resettable
Siren 2, high current output S2
1 A, resettable
Siren 3, high current output S3
1 A, resettable
Mains, mains fuse:
ATS1500A(-IP)
315 mA, fast 20x5
ATS3500A(-IP), ATS4500A-IP
630 mA, fast 20x5
Note: Mains fuse is part of the mains terminal block.