6
Ready Light
The ready light is “on” when the system is ready to arm and “flashesif ready
to force arm. The ready light is off when the system is not ready to arm
because of a zone(s) being faulted.
Stay Light
The stay light is “on when the all interior (motion detector) zones are
bypassed.
Zone Light
The zone lights are “offwhen everything is normal. A zone light will be “onif
the zone has been bypassed. If a zone light is “flashing”, that zone is in alarm
or has been faulted. If a zone light is “flashing” rapidly, it means that the zone
is in a trouble condition. Trouble conditions are:
Tamper
Hardware
Low Battery
Loss of Supervision
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid
“flashing” light for a short period of time, follow ed by a slow “flashinglight.)
EMERGENCY ACTIVATION KEYS
NOTES: You must hold these keys for 2 seconds to activate these
functions. Your system may not be programmed for these activation keys
(see page 1). You should press these keys only in an emergency situation that
requires response by emergency personnel. If your system is programmed for
these functions, the following reports can be sent.
Fire Key This key can activate the fire alarm when pressed for 2 seconds. If
your system is connected to a monitoring center, an emergency report could be
sent to that center. The keypads sound a continuous beeping.
Auxiliary Emergency Key This key can activate the auxiliary alarm when
pressed for 2 seconds. If your system is connected to a monitoring center, an
emergency report could be sent to that center. The keypads sound a
continuous beeping.
Police (Panic/Hold-Up) Key - This key can sound a local audible alarm when
pressed for 2 seconds. If your system is connected to a monitoring center, an
emergency report could be transmitted to that center. NOTE: Some Panic/Hold-
Up alarms are programmed to be silent at the protected site while reporting an
alarm to the monitoring center. Check with your installing company to
determine how your security system will respond to the Panic/Hold-Up
activation. If programmed for Silent Hold-up, the keypads will not sound.
Otherwise, the keypads will sound a continuous beeping.