P/N 466-2912 • REV A • ISS 05JAN17 3 / 3
Timer setting
Time J1 J2
3 minutes (ex-factory)
5 minutes
10 minutes
20 minutes
Safety instructions
WARNING: Do not open the flash housing. Risk of high
voltage.
Battery replacement and removal
Caution: Batteries can explode or cause burns when
recharged, incorrectly (dis)assembled, or exposed to fire or
high temperatures.
Dispose of used battery according to battery directive
instructions and/or as required by local laws. Keep away from
children.
To remove the batteries from the outdoor siren, please pull the
black plastic strap that holds the battery pack. Only replace the
batteries with the standard lithium battery pack BS7201-N. Do
not use a different type of lithium batteries.
Note: The lithium battery pack BS7201-N is not included with
the siren, and must be purchased separately.
Specifications
Power supply specifications
Number and type of
batteries
BS7201-N, 4-cell custom battery pack,
lithium (purchased separately)
Battery capacity 12.5 Ah
Electronics, board
operating voltage
3.0 VDC
Siren/flash light part
operating voltage
12.0 VDC
Battery lifetime (typical) 3 years *
Current consumption –
IO module (typical)
140 µA at 3.0 VDC ± 10%
Current consumption –
siren (typical)
340 mA at 12.0 VDC ± 10%
Current consumption –
beacon (typical)
74 mA at 12.0 VDC ± 10%
Environmental
Operating temperature 25°C to +50°C
Humidity max 95%, non condensing
Shipping weight 2.3 kg
Enclosure dimensions 310 x 222 x 91 mm
EN 50131 grade and
class
Security Grade 2, Environmental
Class III
* Assumption: maximum 20 siren activations of 3 minutes and
beacon activations of 15 minutes per year.
Regulatory information
Manufacturer UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
EU compliance
Certification EN 50131-5-3:2005
EN 50131-5-3/A1:2008
EN 50131-4:2009
Tested and certified by Telefication B.V.
2012/19/EU (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info.
2006/66/EC (battery directive): This product contains
a battery that cannot be disposed of as unsorted
municipal waste in the European Union. See the
product documentation for specific battery
information. The battery is marked with this symbol,
which may include lettering to indicate cadmium
(Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the battery to your supplier or to a
designated collection point. For more information
see: www.recyclethis.info.
UTC Fire & Security hereby declares that this device
is in compliance with the applicable requirements
and provisions of one or more of the Directives
1999/5/EC, 2014/30/EU and 2014/35/EU. For more
information see: www.utcfireandsecurity.com.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
Customer support
For customer support, see www.utcfssecurityproducts.eu