3BChapter 4: Configuring the camera
4. Click Save to save changes.
Alarm parameters
Use this menu to select how external alarm inputs and alarm outputs should be
handled.
Figure 14: Alarm input screen
To set up an external alarm input:
1. In the “Alarm Parameters” folder click the Alarm Input subfolder to open its
screen.
2. Select t one of the external alarm inputs from the Alarm input drop-down list,
A1 or A2.
3. Select the input type in the Relay status box.
Alarm input type refers to the sensor type. You can select Normal Open (NO)
or Normal Close (NC). NO is default.
Note: In order for a camera to record an alarm, the recording schedule and
alarm type must be enabled. See “Defining a recording scheduleon page 34
for fu
rther information.
4. Select how you want to be notified of an external alarm.
Check one or more of the following response methods:
Email l
ink Sends an e-mail to a specified address when there is a
motion detection alarm. No attachment can be sent with the e-
mail.
See “Network parameters” on page 23 for information on
setting up the
e-mail link.
Trigger alarm output Triggers the camera’s alarm output. Up to two alarm outputs
can be selected.
Trigger recording Triggers
the recording to start in the camera.
Note: Only available for cameras with an SDHC card..