T40000RT SERIES
POOL/SPA EQUIPMENT CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
CONTROL PANEL WITH TIME SWITCH FOR INDOOR/OUTDOOR USE
Suitable for Pool Equipment Control and for Direct Connection of Underwater Lights
ELECTRICAL RATINGS: See inside Enclosure Door
Many of today’s energy efficient pools and spas
utilize the advantages of a single electrical panel,
containing all the necessary controls for the safe,
efficient and automatic operation of the pool/spa
equipment. In addition, this Panel can also be
used to control any outdoor equipment, sign or
pump within its rated capacity.
The Transformers supplied in these panels are
specifically designed to supply 12 volts to under-
water pool/spa lights. A grounded shield between
the primary and secondary winding assures safe
operation and the built-in circuit protection will
disconnect power to the transformer in case of
overload. These transformers are suitable for
direct connection to underwater Pool and Spa
lights.
The all-weather enclosure contains a heavy-duty,
industrial grade Time Switch, with mounting
provision for a second Intermatic switching device.
Also, it has provisions to install a switch inside as
well as a switch or GFCI receptacle on the out-
side. The Time Switch can also accommodate an
optional heater control (fireman) switch.
The Control is designed to operate any pump,
within its rated capacity. However, if protection
to prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this Control. Contact pump manufacturer
if not sure and/or for more details.
1
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Transformer Input Secondary Output
Rating
60 Hz.
Lamp Watts* Volts
100W 120V. 1 Amp Max. 100 Max. 12 or 13
300W 120V. 3 Amp Max. 300 Max. 12, 13 or 14
* Any combination of bulbs, any tap.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermatic T40000RT SERIES and is the answer not in the manual?

Intermatic T40000RT SERIES Specifications

General IconGeneral
BrandIntermatic
ModelT40000RT SERIES
CategoryControl Panel
LanguageEnglish

Related product manuals