EasyManua.ls Logo

Intermec IP30 - Understanding the Status Light; Specifications; Where to Find more Information

Intermec IP30
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Understanding the Status Light
Specifications
Electrical requirements: 2-bay charger x 12V, 1.5A
4-bay charger x 12V, 2.4A
8-bay charger x 12V, 4.15A
Operating temperature: 0°C to 35°C (32°F to 95°F)
Storage temperature: -30°C to 70°C (-22°F to 158°F)
Relative humidity: 0% to 95% non-condensing
Where to Find More Information
Go to the Intermec web site at www.intermec.com to find
manuals as PDF files. If you have any problems, please visit
our Product Support web site at intermec.custhelp.com or call
1-800-755-5505.
Color Description
Steady green Battery is fully charged.
Slow flashing
green
Battery is quick charging. Quick charging occurs for
the first hour that the battery is in the charger. After
1 hour, the battery is charged to approximately 75%
capacity.
Fast flashing
green
Battery is charging. A fully discharged battery
charges to 100% capacity in approximately 3 hours.
Flashing red The battery temperature is too cold or too hot for
the battery to charge. Make sure that the temperature
is from 0°C to
35°C (32°F to 95°F).
Steady red The battery is not charging, because the battery is
faulty. Replace the battery.
No light The charger is not operating. Make sure that the:
battery is correctly inserted in the charger.
power supply is properly connected to the charger
and an AC outlet.
battery contacts are clean. To clean the contacts,
rub them with a pencil eraser and remove any
eraser debris.