10.2 - FILTER SUCTION
Before using the machine it is IMPORTANT to make sure that the filter is clean. Wash the fil-
ter under running water and/or with an air pressure gun to totally eliminate any deposits in the
filter.
Remember that a clean filter guarantees the good of the machine operation.
Remove the filter from the water inlet
Clean the filter using an air
pressure gun.
Clean the filter under run-
ning water.
IPX
IP
IP
IP170 IP150 IP130-140
IP SERIES
Oil capacity: 0,09 liters model IP130
0,14 liters model IP140
0,11 liters model IP150
0,22 liters model IP170
• Unscrew the dipstick/discharge plug situated on the pump.
• Empty oil from the pump into a container.
This must later be delivered to an authorised collection centre.
• Pour in the quantity of oil indicated depending on the model.
• Screw in the dipstick/discharge plug.
10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE
Periodically it is necessary to replace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decrease of the working
pressure. Contact your dealer if you wish to purchase a new nozzle.