EasyManua.ls Logo

Interpump Group IP - Filter Suction

Interpump Group IP
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
INLET
INLET
10.2 - FILTER SUCTION
Before using the machine it is IMPORTANT to make sure that the filter is clean. Wash the fil-
ter under running water and/or with an air pressure gun to totally eliminate any deposits in the
filter.
Remember that a clean filter guarantees the good of the machine operation.
Remove the filter from the water inlet
Clean the filter using an air
pressure gun.
Clean the filter under run-
ning water.
IPX
IP
IP
IP170 IP150 IP130-140
IP SERIES
Oil capacity: 0,09 liters model IP130
0,14 liters model IP140
0,11 liters model IP150
0,22 liters model IP170
Unscrew the dipstick/discharge plug situated on the pump.
Empty oil from the pump into a container.
This must later be delivered to an authorised collection centre.
Pour in the quantity of oil indicated depending on the model.
Screw in the dipstick/discharge plug.
10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE
Periodically it is necessary to replace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decrease of the working
pressure. Contact your dealer if you wish to purchase a new nozzle.