Do you have a question about the inTest THERMOSTREAM ATS-545 and is the answer not in the manual?
Information for users, suggesting familiarization with manuals before use.
Details on support services, customer training, repair, spare parts, and technical support.
Information to have ready when calling for support, including software version and model number.
General safety precautions, warnings, and cautions for operating the system.
Specific warnings related to electrical hazards, hot/cold surfaces, and operational safety.
Specific cautions regarding equipment handling, static sensitivity, power, and component safety.
Step-by-step guide for setting up the THERMOSTREAM® System.
Guidelines for selecting a suitable site for the THERMOSTREAM® System.
Instructions for attaching the thermal cap and shroud to the head module.
Identifies rear panel connections for air and power supply.
Details power connection procedures and voltage requirements for system operation.
Details on connecting compressed air supply to the system.
Guide for connecting and attaching thermocouples for temperature measurement.
Methods to optimize test site setup for static, moisture, and temperature protection.
Overview of MobileTempTM Systems for environmental testing with THERMOSTREAM®.
Procedures for starting up and shutting down the THERMOSTREAM® System.
Information on the thermal head and manipulator assembly.
Overview of the Operator Control Module (OCM) for system operation.
Allows running the system to a programmable setpoint (HOT, AMBIENT, COLD).
Allows running the system through 12 programmable setpoints per Program Test Setup.
Overview of the system's communication interfaces for remote control.
Describes the syntax rules for commands sent to and received from the system.
Explains how the system processes commands received from a host.
Details how command and query errors are reported using the IEEE-488 standard.
Settings and configuration for the IEEE-488.2 interface.
Details on the serial interface, including connector pinouts and parameters.
Lists and describes mandatory commands according to IEEE-488.2 standard.
Lists and describes serial commands for RS-232C communication.
Lists and describes commands specific to the THERMOSTREAM® system.
Provides a suggested schedule for preventive maintenance tasks.
Recommendations for regular inspection and cleaning of the system.
Procedures for inspecting and maintaining the system's air path filters.
Procedure for draining moisture from pneumatic filter elements to prevent freeze-up.
Step-by-step guide for replacing the pneumatics filter element.
Instructions for replacing the post filter in the air dryer module.
Procedures for verifying the Device Under Test (DUT) performance.
Procedure for verifying system performance at low temperatures.
Procedure for verifying system performance at high temperatures.
Procedures for calibrating system sensors and components.
Step-by-step guide for calibrating the main air sensor.
Steps for calibrating DUT sensors, specifically Type T or K thermocouples.
Procedure for calibrating the flow board using firmware and software.
Information on Materials Safety Data Sheets for system fluids.
Lists available system drawings and schematics with their respective numbers.
Details the remote interface command set compatibility with older TP04310 models.
| Temperature Stability | ±0.5°C |
|---|---|
| Temperature Accuracy | ±1.0°C |
| Cooling Method | Mechanical refrigeration |
| Transition Time (+125°C to -55°C) | 10 seconds (typical) |
| Transition Time (-55°C to +125°C) | 10 seconds (typical) |
| Power Supply | 50/60Hz |