SERVICE BY QUALIFIED TECHNICIANS (continued)
Regulation (EU) N
o
517/2014 of 16/04/14 on uorinated greenhouse gases
and repealing Regulation (EC) N
o
842/2006
Leak checks
Operators of equipment that contains uorinated greenhouses gases in quantities of 5 tons of
CO
2
, equivalent or more and not contained in foams shall ensure that the equipment is checked
for leaks.
Leak checks frequency – for equipment that contains uorinated greenhouse gases in quantities
of 5 tons of CO
2
equivalent or more, but of less than 50 tons of CO
2
equivalent: at least every
12 months.
Equivalent CO
2
Load in kg and Tons amounting CO
2
Load and Tons amounting CO
2
Frequency of test
From 2 at 30 kg load = from 5 at 50 Tons Each year
Concerning Gas R 410a, 2.39kg amounting at 5 tons of CO
2
, commitment to check each
year.
Training and certication
The operator of the relevant application shall ensure that the relevant personnel have obtained
the necessary certication, which implies appropriate knowledge of the applicable regulations and
standards as well as the necessary competence in emission prevention, recovery of uorinated
greenhouse gases and safe handling of the relevant type and size of equipment covered by the
certicate.
Record keeping
Operators of equipment which is required to be checked for leaks shall establish and maintain
records for each piece of such equipment specifying the following information:
a) The quantity and type of uorinated greenhouse gases installed;
b) The quantities of uorinated greenhouse gases added during installation, maintenance or
servicing or due to leakage;
c) Whether the quantities of installed uorinated greenhouse gases have been recycled or
reclaimed, including the name and address of the recycling or reclamation facility and, where
applicable, the certicate number;
d) The quantity of uorinated greenhouse gases recovered;
e) The identity of the undertaking which installed, serviced, maintained and where applicable
repaired or decommissioned the equipment, including, where applicable, the number of its
certicate;
f) The dates and results of the checks carried out;
g) If the equipment was decommissioned, the measures taken to recover and dispose of the
uorinated greenhouse gases.
The operators shall keep the records for at least ve years, and the undertakings carrying
out the activities for operators shall keep copies of the records for at least ve years.