(307IO) HEAT PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 12/15/2016
English
307
IO
SAVE THESE INSTRUCTIONS
English
Page 7
PRODUCT SPECIFICATIONS
*Measured Condition at 27°C Ambient Air, 27°C Water, 80% Humidity
Heat Output 8.20 kW (27,820 Btu) / hr
Power Consumption 1.71 kW (5,800 Btu) / hr
Coefcient of Performance (COP) 4.7
*Measured Condition at 15°C Ambient Air, 26°C Water, 70% Humidity
Heat Output 6.00 kW (20,358 Btu) / hr
Power Consumption 1.53 kW (5,191 Btu) / hr
Coefcient of Performance (COP) 3.9
General Data
Voltage / Frequency / Phase 220 - 240 V / 50 Hz / 1 PH
Rated current 7 A
Advised fuse ≥16 A
Recommended pool water capacity 10 - 22 m³
Required system water ow rate 2.5 - 10 m³/hr
Maximum water pressure 0.4 MPa
Water pressure drop 14 kPa
Operating water temperature range 15°C - 35°C
Operating air temperature range 8°C - 40°C
Class of protection I
Type of protection IPX4
Heat exchanger Titanium inside a PVC reservoir
Compressor / refrigerant type Rotary / R410A
Refrigerant gas quantity 0.95 kg
Inlet / outlet tting size 50 mm glue tting; 38 mm hose with collar nut
Noise level at 10 m / 1 m 43 dB(A) / 48 dB(A)
Fan input power 80 W
Fan speed 830 - 870 RPM
RCD protection 10 mA
Global warming potential (GWP) 2088
CO
2
Equivalent 1.99 T
Weight Net / Gross 50 / 69 kg
• Pump and pool must be installed and lled with water prior to installation. Two adults required.
• Tools required: one adjustable wrench, one Philip screwdriver.
• The unit will work properly as long as the following three elements are present:
1. Fresh air 2. Electricity 3. Swimming pool water
143.4
85.2
230
198
620
1019
370
324
575.5
17.5
(Unit: mm)
* Pool covered with a solar pool cover