Loading...
103
CD
SAVE THESE INSTRUCTIONS
Page 21
(103CD) MODEL 8111 (MODEL 8110 + MODEL 51) DELUXE SALTWATER SYSTEM (SALT IN POOL) & FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U
12/25/2007
SALTWATER SYSTEM OPERATION
OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS
After the salt is dissolved, but before starting the sanitizer generation be sure
that:
The system is connected to a grounding type receptacle protected by a
ground-fault circuit interrupter (GFCI).
The filter pump operates several minutes before starting the saltwater system
(This removes air pockets and debris in the water hoses).
No air is trapped in any of the hoses. Follow “Filter Pump Operation” above to
release any trapped air.
1. With the Filter Pump turned “ON” and operating. Code “88”
appears on the electronic control station’s LED indicating the
unit is in a Stand-By Mode, this is normal.
2. Unlock keypad controls:
Press and hold button for 2 seconds until you hear a short
“beep”, then press and hold button for another 2 seconds
until you hear the second short “beep”, LED flashes “00”. This
procedure unlocks the keypad control buttons.
3. Set saltwater system operating hours:
Increase the scheduled number of hours of
operation by pressing button, or reduce
by pressing button. See “Operating Time
Table” for pool size and required operating
hours. Press button to select hours
required, press if too many hours were
selected. The built-in timer will now operate
for the number of hours selected at the
same time each day.
NOTE: The saltwater system will not operate if the filter pump is not operating.
4. Re-lock keypad controls:
With the proper hour value showing, press and hold button
for 2 seconds until you hear a long “beep”, then press and hold
button for another 2 seconds until you hear the second
long “beep”. A green LED light on the control panel will light up
within a few minutes, which indicates the saltwater system
starting sanitizer production. Filter pump can be run alone
without the saltwater system, with the proper hour value
showing, press and hold both and buttons for 2 seconds until you hear a
long “beep”. By locking the control buttons into this setting you will prevent
unauthorized changing of the operating cycle.
NOTE: If you forget to Re-lock the keypad controls, the salt system will
automatically lock the keypad controls and start working 1 minute later.
(1 to 12 hours max per cycle)