(130GS) MINI SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/09/2022
130
GS
SAVE THESE INSTRUCTIONS
English
Page 16
TROUBLESHOOTING GUIDE
INSUFFICIENT
CHLORINE
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
Insufficient operating hours of
the Saltwater System.
The salt level in the pool water
is less than 2000ppm. This is
insufficient.
Chlorine loss due to intense
sunlight exposure.
The bather load has increased.
Clogged or dirty electrolytic cell.
High UV level exposure.
Excessive calcium hardness is
present in the pool water.
No power supply.
RCD has not reseted.
A power fuse has blown.
LED failure.
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
Check the salt level with the Test Kit. Adjust
as needed. See “Salt & Pool Water Volumes”.
Use a pool cover when the pool is not in use
and/or when the unit is operating.
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
Cover the pool with a pool cover for 2 days
with the device running and then test the
water using the test strips.
If the pool is clean and clear, add stabilizer
to the water and then test the water with the
device running.
Drain about 20 to 25% of the pool water and
add fresh water to decrease the calcium
hardness. Inspect the electrolytic cell for
scale buildup. Clean the electrolytic cell if
necessary.
Find out the switch and turn on.
Reset the RCD.
Contact Intex Service Center.
PROBLEM CAUSE SOLUTION