14 Technical specifications
The technical information provided hereafter applies to a standard configuration or represents
maximum achievable values. These can change if accessories are added. The precise changes to
these values are detailed in the sections for the respective accessories.
Permissible operating and storage conditions
Temperature range for operation according to ISO 7176-9:
-25° … +50 °C
Temperature range for storage according to ISO 7176-9:
-40° … +65 °C
Electrical system Comet
Comet
HD
/ Comet
Alpine
Motor
10 km/h: S1: 250 W, Max
peak
1200 W
12.8 km/h: S1: 250 W, Max
peak
1200 W
15 km/h: S1: 250 W, Max
peak
1200 W
10 km/h: S1 650 W,
Max
peak
1800 W
Batteries
2 x 12 V/70 Ah (C20) leakproof/gel
2 x 12 V/75 Ah (C20) leakproof/AGM
Main fuse
70 A 100 A
Charging device
Output current
8 A ±
Output voltage
24 V nominal (12 cells)
Input voltage
200 – 250 V nominal
Operating temperature (surroundings)
-25° ... +50 °C
Storage temperature
-40° ... +65 °C