simultaneously the Swing Louver and the Indicator Light buttons for 3 seconds.
When in mute status the sound alarms will remain activated.
IONIZER
Long press for 3 seconds the ‘’SWING LOUVER’’ button to switch on/o the ionizer. Ions
will be released in the air to purify it and remove unpleasant and unhealthy particles.
ULTRAVIOLET TYPE C (UVC)
Long press for 3 seconds the ‘’INDICATOR LIGHT’’ button to switch on/o the ultraviolet
led type C. The UVC led will help eliminate microorganisms such as germs, viruses, bacteria
and fungi.
CHILD LOCK
By long pressing the timer button for 3 seconds, child lock will be activated/deactivated
automatically. The indicator
will remain steadily on the display informing that child lock
is active.
Under Child Lock: All control buttons are deactivated and the unit will
make a beeping sound each time a button is pressed.
All control buttons are activated again, once the Child Lock is deactivated,
if the unit is unplugged or if there is a power failure.
ANTIBACTERIAL FUNCTION
By long pressing the ‘’OPERATION’’ button for 3 seconds the antibacterial function will
be selected. After the completion of each operation the device will not turn o but instead
the antibacterial function will initiate. The fan will operate for 90 minutes ensure that
no water will remain inside the tank that could cause the increase the concentration of
bacteria or mold, thus put your health at risk.
ON-DISPLAY INDICATORS
P1 - AUTO DEFROST
When this unit operates in very low temperatures, possible frost may build up internally. The
device is equipped with an auto-defrost mode. In this event, the P1 indication will activate
on the digital display panel.
Whenever the sensor which is placed on heat exchanger detects temperature under ≤0ºC,
the unit enters defrost mode for 12 minutes. After 12 minutes of defrosting, the sensor
checks temperature again. If temperature rises ≥2ºC, the unit exits defrost mode and defrost
indicator turns o.
This function ensures the safe operation and the ecient performance of the device.


is selected a countdown of the 90 minutes will appear on the
