1.7 Auto-mode
This mode can be selected with the remote controller
and the setting temperature can be changed between
17°C~30°C.
In auto mode, the machine selects cooling, heating, or
fan-only mode on the basis of T (T =T1-Ts).
T Running mode
T>2 Cooling
-2≤∆T2 Fan-only
T<-2 Heating*
Heating*: In auto mode, cooling only models run the fan
The louver operates same as in relevant mode.
If the machine switches mode between heating and
cooling, the compressor will keep stopping for certain
time and then choose mode according to T1-Ts.
If the setting temperature is modified, the machine will
choose running function again.
1.8 Drying mode
Indoor fan speed is fixed at breeze and can’t be
changed. The louver angle is the same as in cooling
mode.
All protections are active and the same as that in
cooling mode.
1.9 Forced operation function
Forced cooling mode:
The compressor and outdoor fan continue to run and
the indoor fan runs at low speed. After running for 30
minutes, the AC will switch to auto mode with a preset
temperature of 24°C.
Forced auto mode:
Forced auto mode operates the same as normal auto mode
with a preset temperature of 24°C.
The unit exits forced operation when it receives the
following signals:
Switch on
Switch off
Timer on
Timer off
Changes in:
mode
fan speed
sleeping mode
Follow me
1.10 Sleep function
The sleep function is available in cooling, heating, or
auto mode.
The operational process for sleep mode is as follows:
When cooling, the temperature rises 1°C (to not
higher than 30°C) every hour. After 2 hours, the
temperature stops rising and the indoor fan is fixed
at low speed.
When heating, the temperature decreases 1°C(to
not lower than 17°C) every hour. After 2 hours, the
temperature stops decreasing and the indoor fan is
fixed at low speed. Anti-cold wind function takes
priority.
The operating time for sleep mode is 7 hours, after
which, the unit exits this mode and switches off.
The timer setting is available in this mode.
1.11 Auto-Restart function
The indoor unit has an auto-restart module that
allows the unit to restart automatically. The module
automatically stores the current settings (not including
the swing setting) and, in the case of a sudden power
failure, will restore those setting automatically within 3
minutes after power returns.
If the unit was in forced cooling mode, it will run in
this mode for 30 minutes and turn to auto mode with
temperature set to 24°C.
If there is a power failure while the unit is running, the
compressor starts 3 minutes after the unit restarts. If
the unit was already off before the power failure, the
compressor starts 1 minute after the unit restarts.
1.12 Refrigerant Leakage Detection
With this new technology, the display area will show “EC”
when the outdoor unit detects refrigerant leakage.
1.13 8°C Heating(Optional)
In heating mode, the temperature can be set to as low
as 8°C, preventing the indoor area from freezing if
unoccupied during severe cold weather.
1.14 Self clean(Optional)
If you press “Self Clean” when the unit is in cooling or
drying mode:
For cooling models, the indoor unit will run in low
fan mode for a certain time, then ceases operation.

Table of Contents

Other manuals for INVENTOR O3MVO32-09

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVENTOR O3MVO32-09 and is the answer not in the manual?

INVENTOR O3MVO32-09 Specifications

General IconGeneral
BrandINVENTOR
ModelO3MVO32-09
CategoryAir Conditioner
LanguageEnglish

Related product manuals