EasyManuals Logo

INVENTOR P9VI32-09WF User Manual

INVENTOR P9VI32-09WF
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
38
stop.
10.4.4 Auto-mode
This mode can be chosen with remote
controller and the setting temperature can be
changed between 17°C ~30°C
In auto mode, the machine will choose cooling,
heating or fan-only mode according to ΔT (ΔT
=T1-Ts).
T 1 -T s
C o o lin g
H e a tin g *
F a n o n ly
Heating*: For cooling only models, they will run
at fan speed
Indoor fan will run at auto fan of the relevant
mode.
The louver operates same as in relevant mode.
If the machine switches mode between heating
and cooling, the compressor will keep stopping
for certain time and then choose mode
according to T1-Ts.
If the setting temperature is modified, the
machine will choose running function again.
10.4.5 Drying mode
Indoor fan speed is fixed at breeze and can’t be
changed. The louver angle is the same as in
cooling mode.
All protections are active and the same as that
in cooling mode.
9.4.6 Forced operation function
Forced cooling mode:
The compressor and outdoor fan keep running
and the indoor fan runs at low speed. After
running for 30 minutes, AC will turn to auto
mode with 24 setting temperature.
Forced auto mode:
The action of forced auto mode is the same as
normal auto mode with 24 setting
temperature.
When AC receives signals, such as switch on,
switch off, timer on, timer off, mode setting, fan
speed setting, sleeping mode setting, follow me
setting, it will quit the forced operation.
10.4.7 Sleep function
10.4.7.1 The sleep function is available in
cooling, heating or auto mode.
10.4.7.2. Operation process in sleep mode is as
follow:
When cooling, the setting temperature rises 1
(be lower than 30) every one hour, 2 hours
later the setting temperature stops rising and
the indoor fan is fixed at low speed.
When heating, the setting temperature
decreases 1 (be higher than 17) every one
hour, 2 hours later the setting temperature
stops rising and indoor fan is fixed at low speed.
(Anti-cold wind function has the priority).
10.4.7.3 Operation time in sleep mode is 7
hours. After 7 hours the AC quits this mode and
turns off.
10.4.7.4 Timer setting is available
10.4.8 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an
auto-restart module. In case of a sudden power
failure, the module memorizes the setting
conditions before the power failure. The unit will
resume the previous operation setting (not
including swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24 setting
temperature
If AC is off before power off and AC is required
to start up now, the compressor will have 1
minute delay when power on. Other conditions,
the compressor will have 3 minutes delay when

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVENTOR P9VI32-09WF and is the answer not in the manual?

INVENTOR P9VI32-09WF Specifications

General IconGeneral
BrandINVENTOR
ModelP9VI32-09WF
CategoryAir Conditioner
LanguageEnglish

Related product manuals