47
11.1 Indoor Unit Error Display
Operation
lamp
Timer lamp
Display
LED STATUS
1 time
X
E0
Indoor unit EEPROM parameter error
2 times
X
E1
Indoor / outdoor units communication error
4 times
X
E3
Indoor fan speed has been out of control
5 times
X
E4
Indoor room temperature sensor T1 open circuit or short
circuit
6 times
X
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
9 times
X
E7
Indoor PCB /Display board communication error
7 times
X
EC
Refrigerant leakage detection
1 times
O
F0
Overload current protection
2 times
O
F1
Outdoor ambient temperature sensor T4 open circuit or
short circuit
3 times
O
F2
Condenser coil temperature sensor T3 open circuit or
short circuit
4 times
O
F3
Compressor discharge temperature sensor T5 open
circuit or short circuit
5 times
O
F4
Outdoor unit EEPROM parameter error
6 times
O
F5
Outdoor fan speed has been out of control
1 times
P0
IPM malfunction or IGBT over-strong current protection
2 times
P1
Over voltage or over low voltage protection
3 times
P2
High temperature protection of IPM module
5 times
P4
Inverter compressor drive error
Olight Xoff ☆(flash