BPD series PV pumping inverter Function parameters
34
Function
code
Name
Detailed description
Default
Modify
parameters of the P02 group) from the keypad to
machine
Note:
After the parameter is set to 1, 2, 3 or 4, and the
operation is executed, the parameter is
automatically restored to 0.
P07.27
Type of the
current fault
0: No fault
1: Inverter unit U phase protection (OUt1)
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection (OUt3)
4: ACC overcurrent (OC1)
5: DEC overcurrent (OC2)
6: Constant-speed overcurrent (OC3)
7: ACC overvoltage (OV1)
8: DEC overvoltage (OV2)
9: Constant-speed overvoltage (OV3)
10: Bus undervoltage fault (UV)
11: Motor overload (OL1)
12: The inverter overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
15: Rectifier module overheat (OH1)
16: Inverter module overheat (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor antotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback disconnection fault (PIDE)
23: Brake unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
2631: Reserved
32: Short-to-ground fault 1 (ETH1)
33: Short-to-ground fault 2 (ETH2)
P07.28
Type of the last
fault
P07.29
Type of the last
but one fault
P07.30
Type of the last
but two fault
P07.31
Type of the last
but three fault
P07.32
Type of the last
but four fault