GD200A series VFD Peripheral options and parts
-170-
Connect the braking resistor or braking unit with the VFD according to the
diagram. Incorrect wiring may cause damage to the VFD or other devices.
Goodrive200A series VFDs of the 030G/037P and lower models need internal braking units and the
VFDs of the 037G/045P and higher models need external braking units. Please select the resistance
and power of the braking resistors according to actual utilization.
Note:
Select the resistor and power according to the provided data.
The braking torque may increase because of the raising of braking resistor. The below table is
calculated at 100% of the braking torque, 10%, 50% and 80%of the braking usage ratio. The user
can select according to the actual working.
Refer to the operation instructions of braking units when using external units for right setting of
voltage degree. Otherwise normal operation of the VFD may be impacted.
100% of
braking
torque
(Ω)
The consumed power of the
braking resistor
Min.
Braking
Resistor
(Ω)