SAF-MI-LBK-SBV-multi-v2.0-print-26000041 |© 2020-2021 Inxpect SpA Installation instructions 19
LBK-C22 digital inputs terminal block
Symbol Description
Type 1
Input 24 V dc type 1
Type 1
Input 24 V dc type 1
Type 2
Input 24 V dc type 2
Type 2
Input 24 V dc type 2
Type 3 Input 24 V dc type 3
Type 3 Input 24 V dc type 3
SNS Input 24 V dc for diagnostics
GND Common reference for all digital inputs
Note: the cables used must have a maximum length of 30 m (98.4 ft) and the operating temperature must
be at least 90 °C.
Note: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm (5 lbs in).
LBK-C22 power supply terminal block
Note: front view of connector.
Symbol Description
+ + 24 V dc
Earth
- GND
Note: the operating temperature of the cables must be at least 80 °C.
Note: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm (5 lbs in).