Drive Specifications
Environmental Limits
Operating Temperature*
Drive with disk inserted ..................... 10° to 51°C (50° to 123°F)
* Operating temperature limits must not be exceeded at the head / disk interface.
Storage Temperature (6 months)
Drive .................................................-22° to 51°C (-8° to 123°F)
Disk ...................................................-22° to 51°C (-8° to 123°F)
Shipping Temperature (96 hours)
Drive ............................................... -40° to 60°C (-40° to 140°F)
Disk ................................................. -40° to 51°C (-40° to 123°F)
Relative Humidity (noncondensing)
Operating humidity ..................................................... 20 to 80%
Storage / Shipping ........................................................ 10 to 90%
Maximum Wet Bulb
Operating .............................................................. 26.7°C (80°F)
Storage / Shipping .................................................. 29.4°C (85°F)
Max Temperature Gradient
Operating ........................................................ 12°C/hr (22°F/hr)
Altitude
Operating ................................................ To 3,048 m (10,000 ft)
Shock
Operating ......................................... 7g,
1
2 sine wave for 11 msec
Shipping (96 hr) ................................................100g for 11 msec
Vibration (Sweep rate = 1 Oct/min)
Operating .............................................0.4g, 0-peak at 5-20Hz
0.2g, 0-peak at 20-250 Hz
Shipping ...............................................1.3g, 0-peak at 5-27 Hz
2.0g, 0-peak at 27-60 Hz
5.0g, 0-peak at 60-500 Hz