ENGLISH
24
After recharging with an
electronic battery-charger the
storage-battery does not show
the correct voltage (about
2,14V for each empty element)
and only one or few elements
turn out to be flat when tested
with densimeter (models with
battery only)
the storage battery has not
been connected to the battery-
charger (for instance because
the low voltage connector of the
battery-charger has been
erroneously connected to the
machine connector)
connect the battery-charger
to the storage battery
connector
the battery-charger and the
power socket to which the
storage battery is connected are
not compatible
check that the power supply
characteristics indicated on
the battery-charger plate are
compliant with those of the
mains
the battery-charger has not
been installed correctly
• taking into account the actual
voltage available at the
socket, check that the
connections of the
transformer primary circuit in
the battery-charger are
correct (at this purpose read
the manual to the battery-
charger)
the battery-charger does not
work
check that there is voltage at
the battery-charger, that the
fuses are not interrupted and
that there is current at the
try to charge by means of
another rectifier: if the
battery-charger does not
work, call the after-sales
service staff communicating
the serial number of the
battery-charger
After recharging with an
electronic battery-charger the
storage-battery does not show
the correct voltage (about
2,14V for each empty element)
and only one or few elements
turn out to be flat when tested
with densimeter (models with
battery only)
one or more elements are
damaged
replace, if possible, the
damaged elements. For
monoblock storage batteries
at 6V or 12V, replace the
whole storage battery
The electrolyte that is present
in the storage battery has a
cloudy colour) (models with
battery only)
the storage battery has
completed the charge/discharge
cycles indicated by the
Manufacturer
• replace the storage battery
the storage battery has been
recharged with a too high current
• replace the storage battery
the storage battery has been
charged beyond the limit
suggested by the Manufacturer
• replace the storage battery