DRAINING THE FLOAT BOWL
1. Turn the starting dial switch to the OFF position.
2. Locate the drain screw on the bottom of the
carburetor float bowl.
3. Place an appropriate gasoline container to catch
the drained fuel.
4. Loosen the float bowl drain screw and allow the
fuel to drain from the drain tube. Tighten the float
bowl drain screw.
DANGER
Explosion and Fire. Fuel and vapors are
extremely flammable and explosive.
Store fuel in a well ventilated area. Keep
fire and spark away. Failure to do so will
result in death or serious injury.
WARNING
Risk of Fire. Verify machine has properly
cooled before installing cover and
storing machine. Hot surfaces could
result in fire.
Page 25
9 - Clean the generator and store in a cool, dry and
well ventilated area out of direct sunlight.
Drain Tube
Bolt
Carburetor
Bolts
Maintenance cover