When the selector is in the “AUTO” position, boiler fun-
ctioning is automatically controlled on the basis of the
temperature levels and time periods set. The second
selector must be in the “RUN” position to start. The pro-
gramming procedure is described below:

Set the selector to the “CLOCK“ position. Press “h” to
change the hour on the display, or “m” to change the
minutes. To set the day, press the “1…7” button until
the arrow is pointing to the correct day (1 = Monday… 7
= Sunday).

The time clock has 8 on times and 8 off times. To make
it easier to use, the time clock is supplied with 3 on
times and 3 off times already set for each day of the
week, as shown below:
To select programmes other than those already set, move
the selector to position “P”; “0:001” will appear on the
display, in which the first three digits indicate the hour
and minutes, while the fourth digit identifies the program
number. Odd-numbered programs identify requests for
operation (day temperature), in which case the light bulb
symbol will appear on the display, while even-numbered
programs identify drops in temperature (night). Use the
“1…7” key to select the day of the week (from 1 to 7) or
days (1 ÷ 5, 6 - 7; 1 ÷ 6 or every day if the program is to be
repeated every day of the week). Set the hour and minutes
with the “h” and “m” buttons. Press “P” to store the ope-
ration in memory and go on to the next program. Repeat
the same procedure to set the
remaining programs.
When finished programming, set the selector to “RUN”
position.

The on and off time must be deleted for each program
to be deleted.
Set selector (2) to position “P”. Select the desired pro-
gram with button (3), then press button (4) to delete the
day setting (the triangular symbols for the days should
go away). If part of the program is deleted, when you
set selector (2) back to the “RUN” position an error will
appear in the clock display, referring to the program
which is incorrect.
To delete all programs, put the selector in position “P”
and press buttons (3) and (5) at the same time.

The SKIP function deactivates programs for the next
day and resumes regular programming 24 hours
later.
This function is useful if you will be out all day and
don’t need heating.
To start this function, press button (7), which is active
only when selector (2) is in “RUN” position.
Once you have selected the SKIP function, it will go into
effect at 0:00 of the next day for 24 hours.
You cannot turn it off once it has started, so regular
programming will not resume until 24 hours have pas-
sed.

Program Time
1 06,00
2 09,00
3 12,00
4 14,00
5 18,00
6 22,00


1 Manual/automatic operation selector
2 Program/schedule setting selector
3 Program button
4 Day of the week button
5 Hour button
6 Minute button
7 SKIP button
8 Reset button