EasyManua.ls Logo

irinox ICY L - User Manual

irinox ICY L
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
N°REV REVISION DESCRIPTION DATE REV. REVISER
00
FIRST EMISSION
01/12/2015
NC
U S E A N D
M A I N T E N A N C E
I N S T R U C T I O N S

Questions and Answers

  • S
    ssosaAug 15, 2025
    How to troubleshoot the front board if it does not turn on in my irinox ICY L?
    • D
      Devin Perry IIAug 15, 2025
      If the front board of your Irinox Refrigerator doesn't turn on, first check the electrical line connection to ensure there is a power supply. If the power supply is fine, inspect the Bus cable and ensure it is correctly inserted in the dedicated connector on both the Front board and the Relay board. Finally, if the issue persists, the protection fuses might be blown, requiring replacement by an authorized technician.
  • W
    wintersmarciaAug 18, 2025
    What to do if the compressor does not work in my irinox ICY L?
    • D
      Daniel MatthewsAug 18, 2025
      If the compressor in your Irinox Refrigerator isn't working, start by checking the electrical line connection to ensure it's properly powered. If the power supply is not the issue, it could be due to several other reasons: blown auxiliary circuit protection fuses (requiring replacement by an authorized technician), intervention of internal Klixson for overload, a tripped circuit breaker switch, a pressure switch intervention for high pressure (ALP alarm), a missing relay board consent, or a broken remote switch. For these issues, intervention of a technician is required.
  • J
    john28Aug 22, 2025
    Why the cell fans do not turn in my irinox ICY L Refrigerator?
    • A
      Alexa FrostAug 22, 2025
      If the cell fans in your Irinox Refrigerator aren't turning, first check the electrical line connection to ensure there is a power supply. If the power supply is fine, it might be due to a broken fan or a broken relay board, both requiring intervention of a technician for replacement.
  • K
    Kenneth SchroederAug 26, 2025
    What to do if the compressor works but it does not cool the cell in my Irinox Refrigerator?
    • P
      Philip GonzalezAug 26, 2025
      If the compressor in your Irinox Refrigerator is running but not cooling the cell, it could be due to several reasons. There might be no refrigerant gas or a broken electrovalve, both requiring intervention of a technician. Alternatively, the condenser might be dirty ('Pulire batteria condensante'). Another possible cause is a broken liquid line electrovalve, which would require a technician to replace the electrovalve or coil.
  • D
    Derek RochaAug 28, 2025
    Why is the condensing fan not working on my irinox ICY L Refrigerator?
    • K
      Kimberly PageAug 28, 2025
      If the condensing fan in your Irinox Refrigerator isn't working, first ensure it has a power supply by checking the electrical line connection. If the power supply is not the issue, it could be due to a broken pressure switch, a broken fan, a broken start condenser, or missing compressor remote switch consent. For all these causes, intervention of a technician is required to replace the device, fan, start condenser, or compressor remote switch.
  • B
    Blake SmithSep 1, 2025
    How to fix the evaporator if it does not defrost in my irinox ICY L?
    • E
      Elizabeth MorenoSep 1, 2025
      If the evaporator in your Irinox Refrigerator isn't defrosting, the defrost cycle programming might be incorrect. Control defrost cycle programming.
  • S
    Sara RodriguezSep 4, 2025
    What to do if there is a door open alarm with door closed in my irinox ICY L?
    • M
      Michele SullivanSep 4, 2025
      If you're experiencing a door open alarm on your Irinox Refrigerator even when the door is closed, it's likely due to a faulty magnetic contact. Technician intervention is required.
  • C
    Chad HernandezSep 7, 2025
    What to do if S2 cell probe is faulty in my Irinox Refrigerator?
    • S
      smithphilipSep 7, 2025
      To address a faulty S2 cell probe in your Irinox Refrigerator, replace the S2 probe.
  • M
    Michele TorresSep 12, 2025
    What to do if there is a total block with probes S1 and S2 faulty in my irinox ICY L Refrigerator?
    • N
      nicole18Sep 12, 2025
      If you are experiencing a total block with probes S1 and S2 faulty in your Irinox Refrigerator because probes S1 and S2 are broken, replace probes S1 and S2.

Summary

Introduction and Safety Information

General Safety Information and Warnings

Key safety standards and warnings for operating the blast chiller.

Installation Guide

Operating the Blast Chiller

Control Panel and User Interface

Description of the touch screen display and its buttons.

Blast Chilling and Freezing Cycles

Detailed explanation of Delicate and Strong cycles for chilling and freezing.

Operation Sequence and Modes

Step-by-step guide for operating the machine, including manual and automatic modes.

Temperature Control and Food Preservation

Guidance on temperature settings for chilling/freezing and post-process food preservation.

Parameter Programming and Customization

Instructions for programming and customizing operational parameters.

Maintenance and Troubleshooting

Troubleshooting and Alarm Management

Guide to identifying and resolving alarms and malfunctions.

irinox ICY L Specifications

General IconGeneral
Brandirinox
ModelICY L
CategoryRefrigerator
LanguageEnglish

Related product manuals