Questions and Answers

  • J
    Jennifer YoungAug 15, 2025
    How to troubleshoot the front board if it does not turn on in my irinox ICY M?
    • J
      Jamie CarrollAug 15, 2025
      If the front board of your Irinox Refrigerator doesn't turn on, first check the electrical line connection to ensure there is a power supply. If the power supply is fine, inspect the Bus cable and ensure it is correctly inserted in the dedicated connector on both the Front board and the Relay board. Finally, if the issue persists, the protection fuses might be blown, requiring replacement by an authorized technician.
  • J
    James PerkinsAug 18, 2025
    What to do if the compressor does not work in my irinox ICY M?
    • A
      Allison MannAug 19, 2025
      If the compressor in your Irinox Refrigerator isn't working, start by checking the electrical line connection to ensure it's properly powered. If the power supply is not the issue, it could be due to several other reasons: blown auxiliary circuit protection fuses (requiring replacement by an authorized technician), intervention of internal Klixson for overload, a tripped circuit breaker switch, a pressure switch intervention for high pressure (ALP alarm), a missing relay board consent, or a broken remote switch. For these issues, intervention of a technician is required.
  • L
    Luke BrownAug 21, 2025
    Why the cell fans do not turn in my irinox ICY M?
    • T
      Tyrone AliAug 21, 2025
      If the cell fans in your Irinox Refrigerator aren't turning, first check the electrical line connection to ensure there is a power supply. If the power supply is fine, it might be due to a broken fan or a broken relay board, both requiring intervention of a technician for replacement.
  • F
    Frank SimsAug 26, 2025
    What to do if the compressor works but it does not cool the cell in my irinox ICY M?
    • T
      Tammy MitchellAug 26, 2025
      If the compressor in your Irinox Refrigerator is running but not cooling the cell, it could be due to several reasons. There might be no refrigerant gas or a broken electrovalve, both requiring intervention of a technician. Alternatively, the condenser might be dirty ('Pulire batteria condensante'). Another possible cause is a broken liquid line electrovalve, which would require a technician to replace the electrovalve or coil.
  • J
    jamesliAug 28, 2025
    Why is the condensing fan not working on my Irinox Refrigerator?
    • M
      Mitchell KingAug 28, 2025
      If the condensing fan in your Irinox Refrigerator isn't working, first ensure it has a power supply by checking the electrical line connection. If the power supply is not the issue, it could be due to a broken pressure switch, a broken fan, a broken start condenser, or missing compressor remote switch consent. For all these causes, intervention of a technician is required to replace the device, fan, start condenser, or compressor remote switch.
  • S
    sharon11Aug 31, 2025
    How to fix the evaporator if it does not defrost in my irinox ICY M Refrigerator?
    • V
      Vincent FisherSep 1, 2025
      If the evaporator in your Irinox Refrigerator isn't defrosting, the defrost cycle programming might be incorrect. Control defrost cycle programming.
  • D
    danielle54Sep 4, 2025
    What to do if there is a door open alarm with door closed in my irinox ICY M?
    • A
      Aaron MillerSep 4, 2025
      If you're experiencing a door open alarm on your Irinox Refrigerator even when the door is closed, it's likely due to a faulty magnetic contact. Technician intervention is required.
  • S
    Samantha DelgadoSep 8, 2025
    What to do if S2 cell probe is faulty in my irinox ICY M Refrigerator?
    • J
      James MooreSep 8, 2025
      To address a faulty S2 cell probe in your Irinox Refrigerator, replace the S2 probe.
  • B
    Brent HaydenSep 12, 2025
    What to do if there is a total block with probes S1 and S2 faulty in my irinox ICY M?
    • T
      torrestammySep 12, 2025
      If you are experiencing a total block with probes S1 and S2 faulty in your Irinox Refrigerator because probes S1 and S2 are broken, replace probes S1 and S2.

Summary

Safety Information

General Safety Standards

Essential safety precautions for operating the blast chiller.

General Documentation

General Warnings

Important safety and usage guidelines for the blast chiller.

Elementary Safety Standards

User liability for negligence and general safety practices.

Installation

Positioning

Recommended placement guidelines and areas to avoid for installation.

Electrical Connection

Instructions for safe and compliant electrical hook-up of the unit.

Information for the Installer

Key information and responsibilities for the installing technician.

Safety and Control Systems

Overview of the machine's safety features and control components.

R404 A Gas Safety Sheet

Safety data sheet for R404A refrigerant, including hazards and first aid.

Operation

Description and Operation

Step-by-step guide for initial setup and cycle selection.

Parameter Programming

Guide to configuring blast chiller cycles and parameters.

Maintenance

Troubleshooting

Guide to identifying and resolving machine issues and alarms.

irinox ICY M Specifications

General IconGeneral
Brandirinox
ModelICY M
CategoryRefrigerator
LanguageEnglish

Related product manuals