EasyManua.ls Logo

irinox ICY M - Extraordinary Maintenance

irinox ICY M
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 12
Fig. 14
Fig. 13
34
4.5.2. How to access the machine electric control
board
• Disconnect the Blast Chiller from the power supply
• Undo the screws on the front finned grid as shown in
fig. 12 with a flat-head screwdriver
• Pull the front finned grill firmly
• Remove the rear protection grid (Fig.14) by undoing
the screws with a flat-head screwdriver
• Remove the left hand side plate (with the machine in
the front position – Fig.13)
• The board is positioned vertically
4.5.3. How to access the condensing plant
(where applicable):
• Remove the rear protection grid by undoing the screws
with a flat-head screwdriver (Fig. 14)
4.5. EXTRAORDINARY MAINTENANCE
4.5.1. How to access the front circuit board
(Touch screen)
The information and instructions in this paragraph are
intended exclusively for specialised personnel, author-
ised to intervene on the electrical and refrigeration parts
of the machine.
• Disconnect the Blast Chiller from the power supply
• Undo the screws on the front finned grid as shown in
fig. 12 with a flat-head screwdriver
• Pull the front finned grill firmly
• Disconnect the board power cord
• Undo the 4 screws on the 4 corners of the board
using a Phillips screwdriver