1.3) MAINTENANCE METER CALIBRATION (RESET)
Set menu 0005 (see Chap.1.1), confirm with the S Key.
The display shows cont.
Press the S Key.
The display shows the work time (maximum time of 3600).
Press the S Key and keep it pressed.
The display shows cont – rESEt alternately.
When the display shows 0000, release the S Key.
The display shows –End–.
Press the S Key to exit. The display shows the Stand-by mode.
End of procedure.