Leaking Error installation
To avoid any leaking during running service
time, it should be observed up to 1mm distance
between the tube end to the double sleeve.
NO
DISCHARGING
TO THE LUBE
POINT.
Air in the centralized
lubrication system
Vent centralized lubrication system.
Pipe blocked or broke
Disconnected the pipe from the output adapter
to visual check if discharging from the
lubrication unit. If so, the lubrication functions.
Check where it blocked or broke in the delivery
pipe and repair.
Gear pump or motor jammed Clean the reservoir and return the
lubrication unit to iSHAN or iSHAN
agents for repair.
No pressure build-in
Check pressure switch. Replace it if failure. If
not, refer to the troubleshooting instruction.
Electric
leakage
If the water comes in contact
with electric wire or earth
faults in electrical appliances.
Indicate with remark where occurred and then
return to iSHAN for repair.
6 Warranty
iSHAN warrants that it will repair or replace any product manufactured and sold by it
which proves to be defective in material or workmanship within a period of one year from
the date of original purchase for the clients. Any warranty claim will be considered invalid
if the product is not complete or it was disassembled or failure to manual or damage caused
by act of God. Any return must consult with iSHAN and obtain iSHAN’s approval before
action.
7Announcement
WarningiSHAN reserves the right to make content and technical changes without
notice and it includes the manual. It is invalid to file a lawsuit against iSHAN in