Summary

Introduction to MINI and MIX Series I;O Modules

Safety Rules and Precautions

Essential safety guidelines for operating and installing the I/O modules.

Technical Specifications Overview

Comprehensive technical data including voltage, power, inputs, outputs, and interfaces.

Power Supply Connection Methods

Instructions for connecting DC and AC power supplies to the I/O modules.

Setting Module Address on Modbus

Procedure for setting the unique Modbus address using rotary switches.

Restoring Default Configuration Settings

Steps to reset all module registers to their factory default values.

Configuration Registers for I;O Modules

Module Address Register

Register 30002: Stores the Modbus module address set by switches.

Local I;O Module Operations

Universal Inputs Connection Methods

Guides for connecting Universal Inputs for voltage, current, temperature, and dry contact.

Universal Inputs MODBUS Registers

Registers for reading Universal Input status, values, and configuration.

Digital Inputs MODBUS Registers

Registers for monitoring Digital Input states and counters.

Analog Outputs MODBUS Registers

Registers for controlling and monitoring Analog Output states and modes.

Special Application Modes Configuration

Details on specific application modes like Time Relay, Heating, and Cooling.

Web Configuration for IP Modules

Local I;O Status and Configuration

Interface for configuring and viewing status of Universal, Digital, and Analog I/O.

IP and Network Configuration

Settings for Ethernet port, Modbus TCP, and BACnet IP.

Modbus TCP;IP Module Functionality

Modbus TCP;IP Client Support

Information on supporting multiple Modbus TCP clients and connection timeouts.

Modbus TCP;IP to RS485 Gateway

Using the module as a gateway to connect RS485 devices via Modbus TCP/IP.

Comprehensive List of Modbus Registers

iSMA iSMA-B-8I-IP Specifications

General IconGeneral
ModeliSMA-B-8I-IP
CategoryI/O Systems
Device TypeInput Module
Input TypeDigital
Number of Inputs8
CommunicationEthernet
Communication ProtocolModbus TCP/IP
Power Supply24 V AC/DC
Operating Temperature-10 to 50 °C