Do you have a question about the iSMA iSMA-B-MIX38-IP and is the answer not in the manual?
Important safety precautions to prevent damage and hazards during installation and operation.
Summary table comparing features across different module types.
Importance and methods of grounding and shielding for noise reduction.
Explanation of RS485 line termination to prevent reflections and signal attenuation.
Procedure for setting the module address using rotary switches S1 and S2.
Table detailing how to select the baud rate using switch S3.
How to select between Modbus RTU, Modbus ASCII, and BACnet using switch S3.
Step-by-step guide to restore the module to its default configuration.
Table listing default values for various registers.
Register 30001 encoding firmware version and module type.
Register 30002 storing the configured Modbus address.
Register 30003 reflecting switch S3 state for baud rate and protocol.
Register 40001 for device actions, 40136 for baud rate, 40137 for stop bits.
Diagram for connecting Universal Inputs to measure 0-10V.
Diagram for connecting Universal Inputs to measure 0-20mA.
Diagram for connecting Universal Inputs for temperature measurement with a thermistor.
Diagram for connecting Universal Inputs as dry contact digital inputs.
Registers for voltage, current, temperature, and resistance measurements.
Table of values for various operation modes like Ordinary IO, Monostable, Bistable Relay.
How to access the web server using IP address and credentials.
Page to configure Universal Inputs, select sensor type, resolution, and filter.
Page for configuring special application modes for inputs.
Page to view and configure Digital Input states and counters.
Page to configure Digital Output states and watchdog.
Page to configure Analog Output values, modes, and default states.
Page to configure RS485 parameters like baud rate, stop bits, and parity.
Page to configure IP address, mask, gateway, and Modbus/BACnet settings.
Description of Modbus TCP/IP client support and connection timeouts.
How modules act as a gateway for RS485 devices via TCP/IP.
| Model | iSMA-B-MIX38-IP |
|---|---|
| Category | I/O Systems |
| Digital Inputs | 8 |
| Universal Inputs/Outputs | 8 |
| Analog Outputs | 4 |
| Relay Outputs | 4 |
| Number of Inputs | 16 |
| Number of Outputs | 12 |
| Communication Protocol | Modbus TCP/IP |
| Power Supply | 24 V AC/DC |
| Protection Class | IP20 |
| Input Type | Universal |
| Humidity Range | 5% to 95% (non-condensing) |
| Weight | 0.3 kg |