Why is the LED light flashing on my ISMOD Electronic Cigarette?
- Eemily09Jul 30, 2025
If the LED light on your ISMOD Electronic Cigarette is flashing, it means the device needs to be charged immediately.
Why is the LED light flashing on my ISMOD Electronic Cigarette?
If the LED light on your ISMOD Electronic Cigarette is flashing, it means the device needs to be charged immediately.
What to do if my ISMOD Electronic Cigarette won't start?
If your ISMOD Electronic Cigarette won't start, there are several possible reasons. If the device hasn't been used for a long time, the power may be completely consumed, and it needs to be charged. If this doesn't help, the button or the LED light indicator may be damaged.
What to do if the LED light flashes with occasional vibrations in ISMOD Electronic Cigarettes?
If the LED light flashes with occasional vibrations, check if the needle of the heating element is damaged.
What to do if the holder for non-combustible tobacco cartridges cannot be placed in the ISMOD device?
If the holder for non-combustible tobacco cartridges cannot be placed in the ISMOD Electronic Cigarette device, clean the heating chamber.
How to properly close the protective cover of ISMOD Electronic Cigarettes?
If the protective cover of your ISMOD Electronic Cigarette cannot be closed and fastened properly, adjust the buttoning direction.
Ensure the device is turned off upon delivery before checking it.
Lists age restrictions and health conditions making the device unsuitable for use.
Keep the device and its components out of reach of children and pets.
Store the device at room temperature, avoiding excessive heat or humidity.
Do not immerse any part of the device in water.
Do not use the device where flammable substances, liquids, gases, or oxygen are present.
Do not use the device while it is charging.
Use only a charging device that meets the specified charging requirements.
Ensure the main body of the device has cooled down before cleaning or contact with internal components.
Use and store the device within an ambient temperature of 5-40°C for optimal performance.
Stop usage immediately and contact service provider if abnormal smell or smoke is noticed.
Avoid skin/eye contact with leaking battery fluid; wash immediately and consult a doctor.
Precautions in the guide cannot cover all possible situations.
Instructions for preparing the device for use, including rotating the dust proof cover.
Guidance on correctly placing the tobacco cartridge into the device chamber.
Details on initiating heating, pre-heating duration, and consumption feedback.
How to enter TA mode and select low, middle, or high temperature settings.
Steps for safely removing the used tobacco cartridge from the device holder.
How to check the battery capacity using the LED light color indication.
Procedure to quickly turn off the device by pressing and holding the switch button.
How to reset the device by inserting a pin into the reset button for malfunctions.
Warnings regarding battery storage, discharge, and handling to prevent damage or hazards.
The ISMOD NANO is a device designed for heating non-combustible tobacco. It features a large-capacity lithium battery, a smart design, and a modular structure, making it easy to carry and use.
Before using the ISMOD NANO, it is crucial to read and understand all safety warnings and instructions. Upon delivery, ensure the device is turned off. This device is not suitable for individuals under 18, children, pregnant or nursing women, or people with certain health conditions such as heart disease, high blood pressure, diabetes, nicotine allergies, or those taking medication for depression, asthma, or other groups.
Keep the device and its components out of reach of children and pets. Store the device at room temperature and avoid exposure to excessive heat or humidity. Never immerse any part of the device in water. Do not use the device in the presence of flammable substances, liquids, gases, or oxygen. The device should not be used while charging. Always use a charging device that meets the specified charging requirements.
Before cleaning, opening, or making direct contact with the internal heating components, ensure the main body of the device has cooled down. The device should be used and stored within an ambient temperature range of 5-40°C. Temperatures outside this range may temporarily reduce battery life or damage the device. If any abnormal situation, such as smell or smoke, is noticed, immediately stop charging and usage, and contact your service provider. In case of battery leakage, avoid contact with skin and eyes; if contact occurs, wash immediately with clean water and consult a doctor. The user guide's precautions do not cover all possible situations.
The ISMOD NANO boasts the following technical specifications:
The device's structure includes:
1. Preparation: To prepare the device, simply rotate the dust-proof cover to open it.
2. Inserting Non-Combustible Tobacco: Place the non-combustible tobacco cartridge upright into the chamber, ensuring the filter remains outside.
3. Heating: To start heating, press and hold the button for 1.5 seconds until the LED flashes white and the device vibrates once. The device will then begin pre-heating, which lasts for 15 seconds. During pre-heating, the LED indicator shows a constant heating mode.
Once the LED indicator light turns solid blue and a second vibration occurs, the device is ready for use, offering 4 minutes and 45 seconds of consumption. When the consumption time reaches the last 30 seconds or the 13th puff, a third vibration will occur, and the LED indicator light will flash white, signaling that the heating period is almost complete. After the entire consumption time is over or after the 15th puff, a fourth vibration will appear, and the LED indicator light will turn off, indicating that the heating process is complete.
Temperature Adjustment Mode (TA): To enter TA mode, press the button 5 times quickly. The LED light color indicates the current temperature setting:
To change the temperature heating mode, press the button quickly 5 times. The LED indicator light will flash green, white, and purple alternately. Wait for the light indicator to perform a self-test (stop shining). Press the button to cycle through heating modes; one click shows the current heating mode. To confirm the selected heating mode, press and hold the power button, or wait 10 seconds to exit TA mode.
4. Removal of Non-Combustible Tobacco Cartridge: To remove the cartridge, press the left push button up, and the non-combustible tobacco cartridge will come out of the cartridge holder. Then, remove the non-combustible tobacco cartridge and twist the protective cap.
5. Cleaning the Heating Chamber: Before cleaning, ensure the device is switched off and has cooled down.
How to use the cleaning sticks:
6. Charger: Connect the USB cable to a charging adapter. The LED light will flash in different colors to indicate the battery power. Once fully charged, the LED light turns off.
1. Indication of Remaining Power: To check the remaining battery capacity when the device is off, click the heating button to activate the LED lamp. The LED light will indicate the remaining battery capacity:
2. Quick Shutdown: Press and hold the switch button for 1.5 seconds after the vibration to quickly shut down the device.
3. Reset: In case of abnormal light flashing or any other malfunction, insert a pin into the reset button to reset the device.
The manual provides a troubleshooting guide for common issues:
| Brand | ISMOD |
|---|---|
| Model | NANO |
| Category | Electronic Cigarettes |
| Language | English |