TEST EQUIPMENT RISK ASSESSMENT (UK RECOMMENDATION)
Users of this equipment and/or their emplo
ers are reminded that Health and Safet
Le
islation require them to
carr
out valid risk assessments of all electrical work so as to identif
potential sources of electrical dan
er and risk
of electrical injur
such as from inadvertent short circuits. Where the assessments show that the risk is si
nificant
then the use of fused test leads constructed in accordance with the HSE
uidance note GS38 “Electrical Test
Equipment for use b
Electricians” should be used.
NOTE :
Particularl
on the 300mV ran
e the displa
ma
fluctuate even with no test leads connected. If this hap-
pens and
ou suspect the readin
s shown on the displa
are not correct, short the "V-
è
-
" and the "COM" input
terminal to
ether and check that the meter shows a readin
of "0".
3.3 Measuring current (µA, mA and A)
1. Plu
the red lead into the "µA mA" or the 10A input terminal and the black lead into the "COM" input terminal .
2. Turn the function switch to "µA", "mA" or "A".
3. A.c. currents can be measured b
pressin
the "AC/DC" button.
4. Appl
the probes to the circuit to the measured.