EasyManua.ls Logo

Iso-Tech IPS3610D - Constant Voltage Operation; Constant Current Operation; Over Voltage Protection

Default Icon
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E3
2-2.Constant Voltage Operation
(1) Output Voltage ranges from 0 to rated voltage with continuous adjustment.
(2) Voltage regulation
line regulation≦5mV.
load regulation≦5mV.
(3) Recovery time≦500µs(50% Load change, minimum load 0.5A).
(4) Ripple & Noise≦5mVrms, 100mVp-p (tested by 20MHz oscilloscope.)
(5) Temperature coefficient≦100ppm/℃.
2-3.Constant Current Operation
(1) Output current ranges from 0 to rated current with continuous adjustment.
(2) Current regulation
line regulation≦3mA.
load regulation≦3mA.
(3) Ripple & Noise≦3mArms (IPS-606D).
≦5mArms (IPS-3610D).
≦10mArms (IPS-1820D).
2-4.Indicator Meter
1)Voltage:
Display : 3 1/2 Digits 0.39” Green LED display.
Accuracy
: ±(0.5% of reading + 2 digits).
2)Current:
Display : 3 1/2 Digits 0.39” Red LED display.
Accuracy
: ±(0.5% of reading + 2 digits).
2-5.Over Voltage Protection
(1) Over Voltage Protection ranges from 5% rating to rating +5.5%.
(2) OVP Accuracy ±(Vset 1%+0.6V)
2-6.Insulation
Between Chassis and Output Terminal
: ≧20MΩ (DC500V).
Between Chassis and AC Cord
: ≧30MΩ (DC500V).