EasyManua.ls Logo

Isonas Pure IP Reader-Controller - Pure IP Reader-Controller (Pure IP Reader-Controller) SPECIFICATIONS

Isonas Pure IP Reader-Controller
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
How to Install the ISONAS PureIP Reader-controller
1.2 : Pure IP Reader-Controller (Pure IP Reader-Controller)
SPECIFICATIONS:
Input Voltage
12 VDC
(8.0V absolute minimum to 14.5V absolute maximum)
PoE per IEEE 802.3af
Note: PoE+ source will negotiate to standard PoE.
Input Current Draw
(Without external loads)
PoE: 2.3 watts
12VDC: 150 mA
Supplied Power for External Devices
(when PoE power is being used)
0.60 AMPS @ 12VDC
Read Range
2 TO 5 inches typically
Read Speed
<250msec (Prox)
Exciter Field Frequency
Proximity -- 125khz
Multi-Tech - 13.56 MHz
Modulation Schemes
Proximity FSK
Multi-Tech --ISO 14443 type A and type B
Communication Interface
TCP/IP Over Ethernet
10 Mbps
Auto Negotiate
Half-duplex / Full-duplex
Inputs
1 Door Sensor / 1 REX/AUX
Outputs
1 Lock Power Output / 1 EDK control output
Standalone Memory Capacity
64000 Cards/ 5000 Events/ 32 Time zones
Visual Indicators
LED for Normal Operations
Operating Temperatures
-40° To 135° Fahrenheit
-40° To 57° Celsius
Weight
Mullion 6.5 Oz
WallMount 8.0 Oz
WallMount w/Keypad 9.5 Oz
Size
Mullion 5.10 x 1.70 x 0.71
WallMount 5.10 x 3.25 x 0.71
WallMount w/Keypad 5.10 x 3.25 x 0.75