WARNING
Donotattempttomeasurecurrentsinhighenergycircuits.Usea
current clamp for measurement needs >10A. The 10A input
terminalisprotectedbyaF15A/250Vfastblowceramicfuse.
①. TurntheSelectorto DC and AC Amps.
②. Connecttheleadsasshown.
③. isnotavailableinDCandACAmps;allotherbuttonscanbeused.
TheDCorACAmpsmeasurementischangedalternativelybyeachpressthebutton .
TheDCandACAmpsMeasurementisasfollows:
1. InserttheblackandredtestleadsintotheCOM and A input terminals respectively.
2. Turnoffordisconnectthecirc uittobemeasuredfromallpowersources,connectthemultimeterin
serieswiththeconductorinwhichthecurrenttobemeasuredflows.
3. Turnonpowertothecircuitundertest.Notethereading,
4. Aftercompletingthemeasurement,turnoffpowe rtothecircuitundertest,disconnectthetestleads
frommultimeter.
5. TheDCandACAmpsmeasurement are always fixed the range.
2-7