WARNING
MeasurementsmustonlybemadewiththecircuitpowerOFF.
①. TurntheSelectorto Diode.
②. Connecttheleadsasshown:Insert the black and red test leads intotheCOM andVΩ
Hz input
terminalsrespectively.
③ . and are notavailable intheDiodetest;allotherbuttonscanbeused.
ThediodeTestisasfollows:
1. Setthe( )positionbyturningtherotaryswitch.
1. InserttheblackandredtestleadsintotheCOM and VΩ
Hz input terminals respectively.
2. Theredleadshouldbeconnectedtotheanodeandtheblackleadtothecathodeofthediode.
3. Thetypicalvoltagedropshouldbeabout0.6Vforsilicondiodeor0.3Vforgermaniumdiode.
4. Ifthediodeisreversebiasedorthereisanopencircuitthereadingdisplayedwillbebetween3.000V
and3.400V.
5. TheDiodetestisalwaysfixedtherange
2-15