EasyManua.ls Logo

Italkero Focus 40 - Manual Operating

Italkero Focus 40
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Final switch-off
The Appliance can be switched off from any heating
position: press the OFF key on the remote control
for a few seconds.
To ensure long battery life, move the switch O I
(5) on the gas valve to “O” position.
The system features an automatic safety lock that
prevents further ignition until it is disengaged (this
operation could take a few minutes).
I
f the appliance is not to be used for a long
period of time, close the gas tap.
MANUAL OPERATING MECHANISM WITH DISEN-
GAGEMENT OF AUTOMATIC
The system features a manual operationmecha-
nism that allows starting the appliance manually in
case of a receiver unit or remote-control unit fault.
Starting the appliance manually
- Disconnect the lead that connects the receiver unit
to the piezoelectric (9) and connect this to the con-
nection (8) on the gas valve.
- Turn the manual operation knob (7) to “MAN” posi-
tion. In this position, access is freed to the magnet
switch (6) and to the piezoelectric spark plug (4).
- Light the pilot flame keeping the magnet switch (6)
pressed with a screwdriver and push the piezoelec-
tric spark plug (4) several times so as to produce a
spark to ignite the flame.
- Keep this pressed for about 15 seconds, until the
pilot flame has stabilised.
If the pilot flame does not stay on once the
switch has been released, repeat the entire
operation.
As soon as the pilot flame is on steady, turn the
manual operation knob (7) to “ON” position.
To regulate the gas, use the second control (1).
The appliance can be disengaged from the manual
operation mechanism by means of the switch “O - I(5).
8
6
4
571
MAX
OFF
9
4
6
23
CUSTOMER SERVICE