Quick Start           
  Copyright © ITECH Electronics Co., Ltd.  10 
Error Information References 
The following error information may occur when an error occurs during Power On 
self-test: 
  If the EEPROM was damaged, the VFD will display “EEPROM Error”. 
  If the lastest operation data in EEPROM is lost, then VFD will display “Error 
Config Data”. 
  If the calibration data in EEPROM is lost, then VFD will display “Error 
Calibration Data”. 
  If the factory calibration data in EEPROM is lost, and then the VFD will display 
“Error Factory Cal.Data”. 
Exception handling 
If the power supply cannot start normally, please check and take measures by 
reference to steps below. 
1.  Check whether the power cord is correctly connected and confirm whether the 
power supply is powered. 
Correct wiring of power cord => 2 
Incorrect wiring of power cord => Re-connect the power cord and check 
whether the exception is removed. 
2.  Check whether the power in On. Power key is under “
” On status. 
Yes => 3 
No => Please check the Power key to start power and check whether the 
exception is removed. 
3.  Check whether the fuse of power supply is burned out. 
If yes, change fuse. Detailed steps: 
1.  Use a screwdriver to push and turn the fuse box on the rear panel of the 
power supply, refer to the below picture.   
     
 
Fuse specification list 
Fuse Sepcification 
(110VAC) 
Fuse Sepcification 
(220VAC)