Command syntaxSTATus:QUEStionable:ENABle <NR2>
Parameter:0~65535
Default setRefer to *PSC command
ExampleSTATus:QUEStionable:ENABle 128
Query syntaxSTATus:QUEStionable:ENABle
Returned parameter<NR2>
STATus: QUEStionable:NTRansition
This command is used to edit the negative transition trigger register of operation event. The
parameter determines which bits of operation event register is 1 will cause the OPER of
status byte register to be 1.
Command syntaxSTATus: QUEStionable:NTRansition <NR1>
Parameter:0~255
ExampleSTATus: QUEStionable:NTRansition 128
Query syntaxSTATus: QUEStionable:NTRansition
STATus: QUEStionable:PTRansition
This command is used to edit the positive transition trigger register of operation event. The
parameter determines which bits of operation event register is 1 will cause the OPER of
status byte register to be 1.
Command syntaxSTATus: QUEStionable:PTRansition <NR1>
Parameter:0~255
ExampleSTATus: QUEStionable:PTRansition 128
Query syntaxSTATus: QUEStionable:PTRansition
STATus:OPERation[:EVENt]?
This command can read the parameter from operation event register. After executing this
order, operation event register is reset.
Query syntaxSTATus: OPERation [:EVENt]?
Parameter: None
Returned parameter<NR1>

Other manuals for ITech IT6512A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6512A and is the answer not in the manual?

ITech IT6512A Specifications

General IconGeneral
BrandITech
ModelIT6512A
CategoryPower Supply
LanguageEnglish

Related product manuals