Function and Features
Copyright© Itech Electronics Co., Ltd. 34
Waveform characteristics are as shown below. Yellow means output voltage
and green means output current.
When CV mode is selected from CC/CV Priority, the load current value
set in List wave file fails and discharge current is the I-set value set in
the power supply Setup menu. Pay attention to current value to avoid
over-current. For detailed checking and setting methods, refer to 3.14
Load Function.
To set loop and CC/CV mode, follow the method below.
1. Press the composite key [Shift]+[P-set] (Menu) to enter the Configuring
Menu.
2. Select CONFIGin the menu and press [Enter] for confirmation.
3. Select Loop-Modewith Right key and press [Enter] for confirmation.
4. Select CV-Loop or CC-Loop to set the loop response speed.
5. Select Priority and set the current priority work mode, which defaults to CV
mode.
3.19 LIST Operation
IT6500C LIST mode comprises 10 files (File1-File10) in total, and each has 10
waves. Each wave has 10 steps. You need to edit the voltage, current, load
current, pulse width and rise/fall slope of each step. Each wave can set
repetition, so does each list file. Ten wave files can be linked in sequence under
one list. Relationship between List file and wave file is shown below.