Function and Features
Copyright© Itech Electronics Co., Ltd. 39
Run the photovoltaic curve.
After set of desired curve, run the photovoltaic analog. The power supply will
change the output voltage and current at 1ms interval to keep the voltage and
current above V/I curve. This speed is enough to meet most trace mechanisms
at maximum power point.
You can set and run local edit curves locally or remotely.
The user-defined 4096-point V/I datasheet can only be set via remote PC, but
can be run locally or remotely.
1. Press [Shift]+ [I-set] (Function) to enter the Menu operation.
2. Select PV-SIM with Left/Right key and press [Enter] for confirmation.
3. Select On or Off. Press [Enter] to switch the current curve status as On.
4. Press [Esc] to exit the main interface, as shown below.
0.00 V 0.00A
0.0W PV-SIM
5. Press [On/Off] to turn on the power supply output. The power supply will
output corresponding voltage based on the current value.
3.21 Built-in Waveform
IT6500C models have built in DIN40839 waveform, ISO-16750-2 waveform and
ISO21848 Provide for user to execute the test directly.
Menu as below:
Road-Vehicles
Vehicle waveform
DIN40839
Evaluation of automotive starting waveform
12V
Select the 12V waveform
24V
Select the 24V waveform
User-define
d
User defined waveform
Off
Disable/Enable the automotive starting
waveform function.
On
ISO16750-2
simulate the waveform to verify the anti-interference
performance of the automotive electronics’ products.
Short-Drop
This test simulates the effect when a
conventional fuse element melts in another
circuit
12V
Select 12V or 24V waveform
24V
Off
Enable or Disable the Short
voltage drop function.
On
Reset-Test
This test verifies the reset behavior of the
DUT at different voltage drops. This test is
applicable to equipment with reset function
Usmin
The minimum supply voltage
Usmin
Off
Enable/Disable this function
On
Starting-Pro
file
This test verifies the behavior of a DUT during
and after cranking.
12V
Select 12V or 24V test system
24V

Other manuals for ITech IT6532C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6532C and is the answer not in the manual?

ITech IT6532C Specifications

General IconGeneral
BrandITech
ModelIT6532C
CategoryPower Supply
LanguageEnglish

Related product manuals