Function and Features
Copyright© Itech Electronics Co., Ltd. 39
Run the photovoltaic curve.
After set of desired curve, run the photovoltaic analog. The power supply will
change the output voltage and current at 1ms interval to keep the voltage and
current above V/I curve. This speed is enough to meet most trace mechanisms
at maximum power point.
You can set and run local edit curves locally or remotely.
The user-defined 4096-point V/I datasheet can only be set via remote PC, but
can be run locally or remotely.
1. Press [Shift]+ [I-set] (Function) to enter the Menu operation.
2. Select PV-SIM with Left/Right key and press [Enter] for confirmation.
3. Select On or Off. Press [Enter] to switch the current curve status as On.
4. Press [Esc] to exit the main interface, as shown below.
0.00 V 0.00A
0.0W PV-SIM
5. Press [On/Off] to turn on the power supply output. The power supply will
output corresponding voltage based on the current value.
3.21 Built-in Waveform
IT6500C models have built in DIN40839 waveform, ISO-16750-2 waveform and
ISO21848 Provide for user to execute the test directly.
Menu as below: