12
Parameter0~255
Reset valueConsult *PSC order
ExampleSTATus:QUEStionable:ENABle 128
Quest syntaxSTATus:QUEStionable:ENABle
Return parameter<NR1>
Reference order*PSC
STATus:OPERation:EVENt]?
This order can read the parameter from operation event register. After executing this order,
operation event register is reset.
Quest syntaxSTATus: OPERation [:EVENt]?
ParameterNone
Return parameter<NR1>
Reference order STATus: OPERation:ENABle
Bit determination of operation event enable register
Bit Position 7 6 5 4 3 2 1 0
Bit Name no use no use no use no use no use no use CC CV
Bit value 2 1
STATus:OPERation:CONDition?
This order can read the parameter from the operation condition. When the parameter of
operation condition register changes, the bit corresponding in operation event register is 1.
Quest syntaxSTATus: OPERation: CONDition?
ParameterNone
Return parameter<NR1>
STATus:OPERation:ENABle
This order can set the parameter of operation even enable register. Setting parameter can
determine which bit value of operation event register is 1 and the bit will enable OPER of
status byte register is 1.
Order syntaxSTATus: OPERation:ENABle <NRf>
Parameter0~255
Reset valueConsult *PSC order
ExampleSTATus: OPERation:ENABle 128
Quest syntaxSTATus: OPERation:ENABle
Return parameter<NR1>
Reference order*PSC
4.3 Output Order
ONPut[:STATe]
This order can set power supply output on or off..
Order syntaxONPut[:STATe] <bool>
Parameter0|1|ON|OFF
*RST valueOFF