EasyManua.ls Logo

ITech IT8512A+ User Manual

ITech IT8512A+
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DC Programmable Electronic
Loads
IT8500plus Series User Manual
Model:IT8511+/IT8511A+/IT8511B+/IT8512+/IT8512A
+/IT8512B+/IT8512C+/IT8512H+/IT8513A+/IT8513B
+/IT8513C+/IT8514C+/IT8514B+/IT8516C+
Version: 2.1

Table of Contents

Other manuals for ITech IT8512A+

Question and Answer IconNeed help?

Do you have a question about the ITech IT8512A+ and is the answer not in the manual?

ITech IT8512A+ Specifications

General IconGeneral
BrandITech
ModelIT8512A+
CategoryTest Equipment
LanguageEnglish

Summary

Safety Precautions

WARNING

Essential warnings for safe operation, covering electrical hazards, damage, and proper grounding.

Chapter 1 Inspection and Installation

Connect the Device Under Test (DUT)

Guides on safely connecting the DUT, including binding posts and remote sensing.

Chapter 2 Quick Start

Front Panel Keys

Explains the functions of various keys and buttons on the front panel.

Power-on Selftest

Outlines the power-on self-test procedure and expected VFD display.

Chapter 3 Functions and Characteristics

Operation Mode

Introduces the four primary operating modes: CC, CV, CR, and CW.

Constant Current Mode (CC)

Details how to set and use the Constant Current (CC) mode, including its I-V curve.

Constant Voltage Mode (CV)

Explains how to set and use the Constant Voltage (CV) mode, including its I-V curve.

Constant Resistance Mode (CR)

Describes the Constant Resistance (CR) mode, its I-V curve, and setup steps.

Constant Power Mode (CW)

Details the Constant Power (CW) mode, its I-V curve, and setup procedure.

LIST Operation

Describes how to use LIST mode for complex sequences and automated testing.

Test Function

Introduces various test functions like transient, OCP, OPP, etc.

Transient Test Function

Details how to perform transient tests in Continuous, Pulse, and Toggled modes.

OCP Test Function

Explains how to perform Over Current Protection (OCP) tests.

OPP Test Function

Details how to perform Over Power Protection (OPP) tests.

Battery Discharge Test

Guides on performing battery discharge tests with various stop conditions.

Saving and Recalling Settings

How to save and recall instrument settings using non-volatile registers.

Chapter 4 Automatic Test Function

Chapter 5 Specifications

Chapter 6 Communication Interfaces