EasyManua.ls Logo

ITech IT8514B+ User Manual

ITech IT8514B+
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DC Programmable Electronic
Loads
IT8500plus Series User Manual
Model:IT8511+/IT8511A+/IT8511B+/IT8512+/IT8512A
+/IT8512B+/IT8512C+/IT8512H+/IT8513A+/IT8513B
+/IT8513C+/IT8514C+/IT8514B+/IT8516C+
Version: 2.1

Table of Contents

Other manuals for ITech IT8514B+

Question and Answer IconNeed help?

Do you have a question about the ITech IT8514B+ and is the answer not in the manual?

ITech IT8514B+ Specifications

General IconGeneral
ModelIT8514B+
CategoryTest Equipment
Voltage Resolution1mV
Operating ModeCC, CV
InterfaceUSB, RS232
ProtectionsOver Voltage Protection (OVP), Over Current Protection (OCP), Over Temperature Protection (OTP)

Summary

Notices

Safety Notices

Defines hazard symbols like CAUTION, WARNING, and NOTE for user guidance.

Quality Certification and Assurance

Safety Precautions

Compliance Information

Chapter 1 Inspection and Installation

1.7 Connect the Device Under Test (DUT)

Outlines steps and safety precautions for connecting the electronic load to the device under test.

Chapter 2 Quick Start

Chapter 3 Functions and Characteristics

3.2 Operation Mode

Details the four primary operating modes: CC, CV, CR, and CW.

3.2.1 Constant Current Mode (CC)

Describes the Constant Current mode, its I-V curve, and how to set current values.

3.2.2 Constant Voltage Mode (CV)

Describes the Constant Voltage mode, its I-V curve, and how to set voltage values.

3.2.3 Constant Resistance Mode (CR)

Describes the Constant Resistance mode, its I-V curve, and how to set resistance values.

3.2.4 Constant Power Mode (CW)

Describes the Constant Power mode, its I-V curve, and how to set power values.

3.9 LIST Operation

Describes how to create and execute complex sequences of load states for automated testing.

3.10 Test Function

Introduces various test functions for evaluating DC sources and batteries.

3.10.1 Transient Test Function

Explains how to perform continuous, pulse, and toggled transient tests.

3.10.2 OCP Test Function

Details the Over Current Protection test procedure and parameters.

3.10.3 OPP Test Function

Details the Over Power Protection test procedure and parameters.

3.10.4 Battery Discharge Test

Guides on performing battery discharge tests with various stop conditions.

3.13 Protection Function

Details the various protection features like OVP, OCP, OPP, and OTP.

Chapter 4 Automatic Test Function

4.2.1 Test Mode for IT8500+

Details the steps for editing and configuring automatic test files in the IT8500+ mode.

Chapter 5 Specifications

Chapter 6 Communication Interfaces

6.2 Communication with PC

Explains how to set up and establish communication between the load and a PC via serial or USB.

Related product manuals