3.4 Manual use
Automatic-mode operations can be executed individually in manual
mode, except for the use of internal car database. To access
manual mode, once the station has been turned on, press DOWN to
commute from AUTO to MAN. The available refrigerant gas quantity
remains still shown on the display.
By pressing OK, it is possible to access the first phase of charging
cycle (RECOVER), which can be run by pressing OK again, or
bypassed by pressing DOWN and switching to the next phase.
Individually-executable phases are the same of automatic mode,
namely:
RECOVER (with de-icing pause)
VACUUM (with leaking test “diagnosis”)
CHARGE OF NEW OIL
CHARGE OF GAS (with sound alarm at end)
For VACUUM, CHARGE OF NEW OIL and CHARGE OF GAS
phases, before their beginning it is possible to adjust times and
quantities by pressing UP, DOWN and OK, in the same way as in
automatic mode ( paragraph 3.3 points 2-3-4).
At the end of each phase, however, the station does NOT switch
automatically to the following step, but requires user intervention.